ComPass A
Short-circuit and earth fault indicator with current monitoring
The ComPass A is a combined short-circuit and earth fault indicator for medium-voltage networks. The device shows all measured values and setting parameters in a menu-guided display and allows them to be reported and parameterized remotely via Modbus protocol. If the adjustable response values are exceeded, a bright red LED flashes. When the rocker switch is pressed, the short-circuits or earth faults are shown in plain text on the display.
Product features
- Short-circuit and earth fault detection from three single-phase current sensors
- LED and OLED display: for good visibility
- Monitoring the variables current (I) and frequency (f)
- Remote signaling via RS485 / Modbus interface and four freely programmable relay contacts
OLED display for good readability
Rocker switch
Multicolor LED
Your added value
- Network utilization visible on site
- Remote signaling of analog values
The 4 relays are set in the event of a fault and all required information is transmitted to the control center via relay contacts and MODBUS. The last 20 events are saved with a date and time stamp as well as fault current information.
Modbus connection
Terminal strip
Technical data
ComPass A | |
---|---|
Short-circuit indicator | ✅ |
Earth fault indicator | ✅ |
Earth fault location method | Earth short circuit |
Measured values / display | Conductor currents I1, I2, I3, IE with phase angleOperating current, I 1,2,3 ø15 min, I 1,2,3 max. 24 h / 7 days / 365 daysLag indicator function I max. LR (last reset)Mains frequency f |
I>> Response values Short-circuit current | 10 – 2,000 A (1 A steps) |
tI>> Response delay | 40 ms – 60 s (10 ms steps) |
IE> Response values earth fault current | 20 – 1,000 A (low-impedance / rigidly earthed network) |
tIE> Response delay | 40 ms – 60 s |
Measuring accuracy phase currents | ±3 % (0 – 630 A, resolution 1 A)±5 % (630 – 1,500 A)±10 % (1,500 – 2,000 A) |
Display |
|
Remote notification / communication |
|
Remote signaling contact | 4 permanent or wiping contacts (1 s), NC or NO contactContact rating: 230 V AC / 1 A / 62.5 VA max.;220 V DC / 1 A / 60 W max. |
Reset |
|
Supply | |
External auxiliary voltage | 24 V – 230 V AC / DC (±10 %) |
Internal power supply | Long-life lithium cell, service life ≥20 years, >1,000 h total flashing time of the LED, >1,000 activations of the display |
Housing | Polycarbonate, IP40 |
Temperature range | -30 °C to +70 °C |
Alle wichtigen Dokumente zum Gerät
Benötigen Sie zusätzliche Informationen zu unserem Gerät? In unserem Download-Bereich finden Sie alle relevanten Dokumente wie Prospekte und Produktkataloge, Fachberichte, Bedienungsanleitungen und Maßzeichnungen (Login notwendig). Klicken Sie einfach auf den Download-Bereich, um die gewünschten Unterlagen zu erhalten.
Matching articles
PERFECT MATCH
Here you will find the matching equipment set and accessories for this item. All components are technically matched to each other and guarantee optimum functionality. For customer-specific requirements and individual offers, please contact our sales department.
Product finder
Find the right Horstmann product for your application quickly and easily.
Other short-circuit and earth fault indicators
ComPass A 2.0
- Load current monitoring
- Detection of earth faults and short circuits for NOSPE/ KNOSPE networks
- Error display without direction indication
ComPass B
- Highly accurate monitoring
- Detection of earth faults and short circuits for all networks
- Remote signaling via RS485 / Modbus interface
ComPass B 2.0
- Highly accurate monitoring
- Detection of earth faults and short circuits for all networks
- Error direction display
ComPass Bs 2.0
- Fault direction indicator with monitoring
- Detection of earth faults and short circuits for all networks
- Switching ComPass Bs 2.0 for controlling a switch-disconnector or circuit-breaker remotely